Description

Electronic Engine Controller 1

ID Breakdown

  • PGN: 61444
  • Source Address: 00
  • Destination Address: (PS): 04
  • PDU Format (PF): F0
  • Data Page: b00
  • Priority: 3

Data Packet Breakdown:

Name Size Byte Offset
Engine Torque Mode 4b 1.1
Actual Engine - Percent Torque (Fractional) 4b 1.5
Driver’s Demand Engine - Percent Torque 1B 2
Actual Engine - Percent Torque 1B 3
Engine Speed 2B 4-5
Source Address of Controlling Device for Engine Control 1B 6
Engine Starter Mode 4b 7.1
Engine Demand ? Percent Torque 1B 8