0CF00400
Description
Electronic Engine Controller 1
ID Breakdown
- PGN: 61444
- Source Address: 00
- Destination Address: (PS): 04
- PDU Format (PF): F0
- Data Page: b00
- Priority: 3
Data Packet Breakdown:
Name | Size | Byte Offset |
---|---|---|
Engine Torque Mode | 4b | 1.1 |
Actual Engine - Percent Torque (Fractional) | 4b | 1.5 |
Driver’s Demand Engine - Percent Torque | 1B | 2 |
Actual Engine - Percent Torque | 1B | 3 |
Engine Speed | 2B | 4-5 |
Source Address of Controlling Device for Engine Control | 1B | 6 |
Engine Starter Mode | 4b | 7.1 |
Engine Demand ? Percent Torque | 1B | 8 |